{"id":20,"date":"2024-09-07T16:41:58","date_gmt":"2024-09-07T14:41:58","guid":{"rendered":"https:\/\/192.168.1.105\/wordpress\/?page_id=20"},"modified":"2026-07-26T10:55:44","modified_gmt":"2026-07-26T08:55:44","slug":"technik","status":"publish","type":"page","link":"https:\/\/www.db0npr.de\/index.php\/technik\/","title":{"rendered":"Info \/ Technik \/ QRG"},"content":{"rendered":"\r\n<h2 data-path-to-node=\"3\">Info \/ Technik \/ QRG<\/h2>\r\n<p data-path-to-node=\"4\">Hier findest du alle technischen Details, Frequenzen und Hardware-Spezifikationen rund um das Relais <b data-path-to-node=\"4\" data-index-in-node=\"101\">DB0NPR<\/b>.<\/p>\r\n<h3 data-path-to-node=\"6\">\ud83d\udd0b Notstrom- &amp; Krisenkonzept<\/h3>\r\n<p data-path-to-node=\"7\">Das gesamte System ist f\u00fcr den Ernstfall ger\u00fcstet: Bei einem Stromausfall ist das Relais auf eine <b data-path-to-node=\"7\" data-index-in-node=\"98\">100 Ah LiFePO4-Batterie<\/b> umschaltbar.<\/p>\r\n<ul data-path-to-node=\"8\">\r\n<li>\r\n<p data-path-to-node=\"8,0,0\"><b data-path-to-node=\"8,0,0\" data-index-in-node=\"0\">Betriebsdauer:<\/b> ca. 60 Stunden autarker Funkbetrieb (je nach Auslastung).<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"8,1,0\"><b data-path-to-node=\"8,1,0\" data-index-in-node=\"0\">Nachhaltigkeit:<\/b> Eine solare Nachladung vor Ort ist vorbereitet und m\u00f6glich.<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-path-to-node=\"10\">\ud83d\udce1 70cm MMDVM-Multimode Relais<\/h3>\r\n<p data-path-to-node=\"11\">Das Herzst\u00fcck f\u00fcr FM, DMR, D-STAR und C4FM. Das verbaute <b data-path-to-node=\"11\" data-index-in-node=\"57\">MMI (MultiModeInterface)<\/b> erkennt automatisch, ob ein digitales oder analoges Signal anliegt, und leitet es nahtlos an den MMDVM- (digital) oder SVXLINK-Zweig (analog) weiter.<\/p>\r\n<h4 data-path-to-node=\"12\"><b data-path-to-node=\"12\" data-index-in-node=\"0\">Standort &amp; Betriebsdaten<\/b><\/h4>\r\n<ul data-path-to-node=\"13\">\r\n<li>\r\n<p data-path-to-node=\"13,0,0\"><b data-path-to-node=\"13,0,0\" data-index-in-node=\"0\">Standort:<\/b> Breitscheid \/ Westerwald (B\u00e4renkopf \u2013 Naturpark Rhein-Westerwald)<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"13,1,0\"><b data-path-to-node=\"13,1,0\" data-index-in-node=\"0\">Koordinaten:<\/b> 50\u00b0 33&#8242; 51&#8243; N \/ 07\u00b0 27&#8242; 16&#8243; O <i data-path-to-node=\"13,1,0\" data-index-in-node=\"43\">(Hinweis: Koordinaten korrigiert auf Basis des B\u00e4renkopfs)<\/i><\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"13,2,0\"><b data-path-to-node=\"13,2,0\" data-index-in-node=\"0\">Locator:<\/b> JO30RN | <b data-path-to-node=\"13,2,0\" data-index-in-node=\"18\">H\u00f6he:<\/b> 348 m \u00fc. NN<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"13,3,0\"><b data-path-to-node=\"13,3,0\" data-index-in-node=\"0\">Inbetriebnahme:<\/b> 29.04.2024<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"13,4,0\"><b data-path-to-node=\"13,4,0\" data-index-in-node=\"0\">Verantwortlich:<\/b> Joachim (DG8JT) \u2013 Betreiber, Zuteilungsinhaber &amp; Sysop<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h4 data-path-to-node=\"14\"><b data-path-to-node=\"14\" data-index-in-node=\"0\">Frequenzen &amp; Technik<\/b><\/h4>\r\n<table data-path-to-node=\"15\">\r\n<thead>\r\n<tr>\r\n<td><strong>Parameter<\/strong><\/td>\r\n<td><strong>Wert \/ Spezifikation<\/strong><\/td>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><span data-path-to-node=\"15,1,0,0\"><b data-path-to-node=\"15,1,0,0\" data-index-in-node=\"0\">Ausgabe (TX)<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,1,1,0\">439,2125 MHz (CTCSS 103,5 Hz)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,2,0,0\"><b data-path-to-node=\"15,2,0,0\" data-index-in-node=\"0\">Eingabe (RX)<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,2,1,0\">431,6125 MHz (CTCSS 103,5 Hz)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,3,0,0\"><b data-path-to-node=\"15,3,0,0\" data-index-in-node=\"0\">Ablage \/ Kanal<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,3,1,0\">-7,6 MHz \/ RU737<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,4,0,0\"><b data-path-to-node=\"15,4,0,0\" data-index-in-node=\"0\">Bandbreite \/ Modulation<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,4,1,0\">12,5 kHz \/ FM &amp; Digital<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,5,0,0\"><b data-path-to-node=\"15,5,0,0\" data-index-in-node=\"0\">Strahlungsleistung<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,5,1,0\">15 Watt (EIRP)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,6,0,0\"><b data-path-to-node=\"15,6,0,0\" data-index-in-node=\"0\">Antennenanlage<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,6,1,0\">Groundplane V-2000 (10 m \u00fcber Grund)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,7,0,0\"><b data-path-to-node=\"15,7,0,0\" data-index-in-node=\"0\">Transceiver<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,7,1,0\">2x Motorola GM-360 (Sender &amp; Empf\u00e4nger)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,8,0,0\"><b data-path-to-node=\"15,8,0,0\" data-index-in-node=\"0\">Duplex-Weiche<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,8,1,0\">Procom DPF 70\/6<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,9,0,0\"><b data-path-to-node=\"15,9,0,0\" data-index-in-node=\"0\">Hardware \/ DV-Modem<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,9,1,0\">Raspberry Pi 3B+ mit MMI-Platine &amp; STM32-DVM auf Arduino DUE<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"15,10,0,0\"><b data-path-to-node=\"15,10,0,0\" data-index-in-node=\"0\">Software<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"15,10,1,0\">Linux + SVXLINK + MMDVMHost + ircddbgateway (G4KLX)<\/span><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3 data-path-to-node=\"17\">\ud83c\udf99\ufe0f 2 Meter EchoLink &amp; FM-Zugang<\/h3>\r\n<p data-path-to-node=\"18\">Dieser Zugang ist direkt an das <b data-path-to-node=\"18\" data-index-in-node=\"32\">FM-Funknetz<\/b> angebunden.<\/p>\r\n<table data-path-to-node=\"19\">\r\n<thead>\r\n<tr>\r\n<td><strong>Parameter<\/strong><\/td>\r\n<td><strong>Wert \/ Spezifikation<\/strong><\/td>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><span data-path-to-node=\"19,1,0,0\"><b data-path-to-node=\"19,1,0,0\" data-index-in-node=\"0\">Frequenz (Simplex)<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,1,1,0\">145,2375 MHz (CTCSS 103,5 Hz)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"19,2,0,0\"><b data-path-to-node=\"19,2,0,0\" data-index-in-node=\"0\">Modulation \/ Bandbreite<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,2,1,0\">FM \/ 12,5 kHz<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"19,3,0,0\"><b data-path-to-node=\"19,3,0,0\" data-index-in-node=\"0\">Strahlungsleistung<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,3,1,0\">10 Watt<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"19,4,0,0\"><b data-path-to-node=\"19,4,0,0\" data-index-in-node=\"0\">Antennenanlage<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,4,1,0\">Procom CXL 2-1\/Lw<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"19,5,0,0\"><b data-path-to-node=\"19,5,0,0\" data-index-in-node=\"0\">Hardware<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,5,1,0\">Raspberry Pi 4 mit Elenata-Platine<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span data-path-to-node=\"19,6,0,0\"><b data-path-to-node=\"19,6,0,0\" data-index-in-node=\"0\">Transceiver<\/b><\/span><\/td>\r\n<td><span data-path-to-node=\"19,6,1,0\">Motorola GM380<\/span><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<h3 data-path-to-node=\"21\">\ud83c\udf24\ufe0f DTMF-Steuerung: Wetterdaten auf Abruf <i data-path-to-node=\"21\" data-index-in-node=\"42\">(Neu seit Mai 2026)<\/i><\/h3>\r\n<p data-path-to-node=\"22\">Du kannst aktuelle Wetterdaten und amtliche Unwetterwarnungen direkt per DTMF-Befehl \u00fcber das Relais abfragen. Ein Hintergrund-Skript holt die Daten live aus dem Internet, wandelt sie per Text-to-Speech in Sprache um und strahlt sie aus.<\/p>\r\n<blockquote data-path-to-node=\"23\">\r\n<p data-path-to-node=\"23,0\">\ud83d\udca1 <b data-path-to-node=\"23,0\" data-index-in-node=\"3\">Bedienung:<\/b> Sende einfach w\u00e4hrend des ge\u00f6ffneten Relais eine der folgenden DTMF-Sequenzen (ohne Sternchen):\u00a0<\/p>\r\n<\/blockquote>\r\n<ul data-path-to-node=\"24\">\r\n<li>\r\n<p data-path-to-node=\"24,0,0\"><code data-path-to-node=\"24,0,0\" data-index-in-node=\"0\">\u00a0 \u00a0 \u00a040#<\/code> \u2013 <b data-path-to-node=\"24,0,0\" data-index-in-node=\"6\">Aktuelles Wetter:<\/b> Kurzbericht f\u00fcr den Landkreis Neuwied.<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"24,1,0\"><code data-path-to-node=\"24,1,0\" data-index-in-node=\"0\">\u00a0 \u00a0 \u00a041#<\/code> \u2013 <b data-path-to-node=\"24,1,0\" data-index-in-node=\"6\">Unwetterwarnung AK:<\/b> Aktuelle Warnungen des DWD f\u00fcr den Kreis Altenkirchen (falls keine Warnung vorliegt, erfolgt keine Ansage).<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"24,2,0\"><code data-path-to-node=\"24,2,0\" data-index-in-node=\"0\">\u00a0 \u00a0 \u00a042#<\/code> \u2013 <b data-path-to-node=\"24,2,0\" data-index-in-node=\"6\">Unwetterwarnung NR:<\/b> Aktuelle Warnungen des DWD f\u00fcr den Kreis Neuwied (falls keine Warnung vorliegt, erfolgt keine Ansage).<\/p>\r\n<\/li>\r\n<li>\r\n<p data-path-to-node=\"24,3,0\"><code data-path-to-node=\"24,3,0\" data-index-in-node=\"0\">\u00a0 \u00a0 \u00a043#<\/code> \u2013 <b data-path-to-node=\"24,3,0\" data-index-in-node=\"6\">3-Stunden-Trend:<\/b> Wettervorhersage f\u00fcr die kommenden 3 Stunden im Kreis Neuwied.<\/p>\r\n<\/li>\r\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Info \/ Technik \/ QRG Hier findest du alle technischen Details, Frequenzen und Hardware-Spezifikationen rund um das Relais DB0NPR. \ud83d\udd0b Notstrom- &amp; Krisenkonzept Das gesamte System ist f\u00fcr den Ernstfall ger\u00fcstet: Bei einem Stromausfall ist das Relais auf eine 100 Ah LiFePO4-Batterie umschaltbar. Betriebsdauer: ca. 60 Stunden autarker Funkbetrieb (je nach Auslastung). Nachhaltigkeit: Eine solare <a class=\"more-link\" href=\"https:\/\/www.db0npr.de\/index.php\/technik\/\">Weiterlesen\u00a0\u2026<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-20","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/pages\/20","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/comments?post=20"}],"version-history":[{"count":2,"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/pages\/20\/revisions"}],"predecessor-version":[{"id":1017,"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/pages\/20\/revisions\/1017"}],"wp:attachment":[{"href":"https:\/\/www.db0npr.de\/index.php\/wp-json\/wp\/v2\/media?parent=20"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}